Working on a hospital project where there are currently fully recessed electric water coolers off 8 foot corridors.
Double water fountain ada clearance.
Beyond a depth of 8 measured from the leading edge the 27 minimum high knee clearance can reduce 18 to the 9 toe space over a 3 span.
Of course the bottled water industry has boomed.
The front edge of the fountain must extend 17 to 19 inches 430 485 mm from the wall.
Spout height and knee clearance.
They should also have a minimum clear floor space of 30 by 48 for wheelchair accommodation.
Drinking water has become vogue again.
Even briefcases and purses have sleeves to hold water bottles.
The new water coolers need to be ada compliant and with bottle filling capability.
But now there seems to be a backlash on the bottled water industry.
Where drinking fountains are provided access is required for both people who use wheelchairs and for standing persons.
Latch side clearance is required if the depth is 60 min.
This dual access must be provided on each floor of a facility equipped with drinking fountains as well as an exterior site and each secured area of a building where drinking fountains are provided.
According to nfpa 101 2018 version 18 2 3 4 5 permits fixed furniture to encroach into the corridor as long as a 6 foot clearance is achieved.
The clearance between the car platform sill and the edge of any hoistway landing shall be 1 1 4 inch 32 mm maximum.
On the pull side of hinge approaches 36 min.
If the latch side clearance is at least 42.
When the knee and toe depth exceeds the 17 minimum the additional space must provide full knee clearance at least 27 high.
Everyone seems to be carrying a bottle of water.
Prodrinkingfountains offers top quality ada compliant drinking fountains and water coolers from the best manufacturers in the water cooler industry.
Federal accessibility code requires that where drinking fountains are provided on an exterior site or on an interior floor no fewer than two one standard one accessible or one hi lo drinking fountain an accessible standard combination unit shall be provided and those with leading edges more than 27 above the floor must be placed in an alcove space or between wing walls not to protrude more than 4 into the circulation path.
The 27 inches 685 mm high minimum clear knee space must be free of equipment or obstructions for a minimum of 8 inches 205 mm extending from the front edge of the fountain back toward the wall.
If your facility needs handicap accessible ada compliant drinking fountains or water coolers we have an excellent selection to choose from.
Turning space 304.
The depth can be 54 min.